Our most capable tester for complex assemblies.
The Cirris CH2 has the power to test thousands of points. Connect the CH2 to your PC and use Cirris Easy-Wire™ software for hipot (HV) testing of complex cables and harnesses.
Info
Test Complex Assemblies
- Scanner chassis measures 17" x 17" x 6" and weighs 40 lbs.
- Up to five 160 point scanner boxes (800 pts/box)
- Tests up to 100,000 points
- 1500 VDC
- 1070 VAC
- Easily rack-mounted for larger applications
- Performance Check Kit for ISO 9000 certification
Software
- Easy-Wire software provides full SPC data collection
- Collect test results by operator, test station, or product
- Customize any standard test report
- Password-protected security
- Limit operator access to system features.
- Online help system
Efficient and Adjustable
- Smart-Lights capable
- Zero Defect Guided Assembly Aid
- Built in digital I/O
- 8 programmable inputs and 8 outputs
- Marking/stamping machines
- Fixture locks
- Pushback modules
- Energizing relays
Specs
Test Points
160 to 800 points; expandable to 100,000 points in 160-point increments. (Max distance from base unit: 200 ft.)
Low Voltage Test
2 Wire
- Voltage: Standard 2.5 V max
- Current: 1 μA, 10 μA, 100 μA, 1 mA, 10 mA ±2%
- Resistance: 0.1 Ω to 1M Ω ±2% ±0.1 Ω
4 Wire
- Voltage: Standard 2.5 V max
- Current: 2 μA, 20 μA, 200 μA, 2 mA, 20 mA,
200 mA, 2 A ±2% - Resistance: 0.001 Ω to 100 Ω ±2% ±0.001 Ω
Components Test
- Diodes: 0 to 2.5 V
- Resistors
- (2-wire) 0.1 Ω to 1 MΩ ±2%
- (4-wire) 0.001 Ω to 1 MΩ ±2% ±0.001 Ω
- Capacitors: 10 pF to 5000 μF ±10% ±50 pF
- Twisted Pairs: Verify proper pairing in twisted pair cables
High Voltage Test
Insulation Resistance Test
- Voltage: 100 to 1500 VDC ± 5%, 10 to 100 VDC ± 5V
- Resistance: 5 MΩ to 1000 MΩ ±10%
Dielectric Withstand Test
- DC Voltage: 100 to 1500 VDC ± 5% or 10 to 100 VDC ± 5V
- AC Voltage: 100 to 1070 VAC ± 5%, 10 to 100 VAC ± 5V
- Current Limit: (DC) 10 μA to 2.5 mA, (AC) 10 μA to 2.5 mA (RMS)
- Max Capacitance Per Net: 30 nF @ 1500 VDC, 9.5 nF @ 1000 VAC
- HV Energy Limit: 35 mJ
- HV Charge Limit: 45μC
Max Points Per Net
Unlimited
Digital Input/Output
8 Inputs / 8 Outputs, 30 V Open collector, +12 V and +5 V each current limited to 100 mA
Test Point Interface
96 pos. Female VME Eurocard connector-32 pos. loaded
PC Requirements
Test Station: 2.0 GHz min. processor speed, Windows 10®, 15 GB hard drive space, 4 GB RAM, 256 MB min. video memory, 1024 x 768 min display resolution, sound (for audible feedback), USB 2.0 or 3.0 port.
Optional Network Database Server: As above except no sound or USB ports required. Windows 10®, Windows Server 2012® or Windows Server 2016® OS.
Power
115 / 230 V 50/60 Hz
Dimensions (width x height x depth)
17.4 x 6.3 x 17.4 in. (44.1 x 16.0 x 44.2 cm)
Note, all dimensions are are rounded up from their real measurements.
Weight
42 lbs (19kg) (fully loaded base or expansion enclosure)
Options
CH2 - Energization Box
- Energize lamps, LEDs, relays or other devices needing external power
- Connected to a CH2 test system using the same cable as a standard expansion box
- Design your test to accommodate a wide variety of external power needs using Easy-Wire software
- Power supply port on the back of the box to plug in your selected power supply
- Optional Programmable Power Supply
- adjust voltages to multiple values within one test program
- Additional information:
- Energization Specifications:
- Energization Points: 160 - 800 Points (in 160 pt. increments)
- Max Current: 2 AMPs
- Fixed Voltage Supplies: 5, 12, 15, 24, 28, & 48 Volts
- Agilent Variable Supply: 0 to 60 Volts
- Interfacing to E-Unit: Standard AC61-KF cabling
CH2 Advanced Instructions
- Add-in set of test instructions to expand the capability of the tester
- Integrate external meters, such as a Keithley 24xx series source meters or Agilent 344xx series DMMs to make high accuracy measurements using those instruments
- Integrate a variable power supply when using the Energization Module
- Different voltages for different applications in the same test program
- Test: Transzorbs, Zener Diodes, Gas Discharge Tubes etc.
- Test Relays: Single Coil, Multi Coil, Pull-in-voltages, Drop-out-voltages etc.
- Test Light/Indicators: Single Lamp to 60V, Multi Lamps up to 60V
- Test Leakage Current: Diodes, Transistors, MOSFET's, Integrated Circuits, etc.
- Highly Accurate Voltage or Current Measurements: With integrated Keithley 2400 series meter
CH2 Adapter Panel System
- Adapter panel mounts directly to the front of the CH2 tester
- adapt from the 32 pin Eurodin style connectors to mating connectors of your choice
Performance Verification
- The CH2 Performance Check Kit allows you to verify the calibration and proper operation of the CH2 tester.
- For information on tester calibration, click here.