About Us
Events
Blogs
Careers
FAQ

CH2 testers not booting. Error #601, #617 and #620

CH2 testers not booting. Error #601, #617 and #620

If you are running Easy-Wire™ version 2011.3.x or earlier you may receive one of the following error messages while trying to boot your CH2 system (due to a hardware change in the CH2’s high-voltage card):

#601  Base Unit Error: (“Hardware error “#25 SyncHVSine Failed”)

#617  HV Supply Failed to Initialize. The HV supply is reporting an initialize error (DW DAC=0, IR DAC = 0)

#620 Self Test Failure (HV). The high voltage supply failed self test at 1000Vac

To resolve the issue install Easy-Wire 2012.2.x or newer.