Tensile Strengths (lbs)

GaugeSAE AS7928 Table IIMIL-T-7928G (for ref.)U.L. 486A TerminalsU.L. 486C SplicesDIN 41611/3NASA-STD 8739.4
32         1.4  
30         2.1  
28         3.2 5
26 7 7 3 3 5.0 8
24 10 10 5 5 8.1 8
22 15 15 8 8 11.1 13
20 19 19 13 10 17.1 21
18 38 38 20 10 25.2 32
16 50 50 30 15 39.8 41
14 70 70 50 25 58.0 65
12 110 110 70 35 92.1 103