Specifications
Capacity
Expandable from 256 to 32,000 points in 256-point increments.
Base Scanner:
256 points, one required per test system
Add-on Scanner:
256 points, no power required
Booster Scanner:
256 points, one required after each 7 add-on scanners
Test Levels
Voltage:
10 volts at < 6.5mA max
Resistance:
0.1 ohm to 100k ohms ±3% ±0.1 ohm, 100k ohm to 1M ohm ±5%
4 Wire (Kelvin Test) Resistance:
.001 ohm to 75 ohms ±3% ±0.010 ohm.
Capacitance:
100pF to 1000µF ±10%
Components Tested:
resistors, diodes, LEDS, capacitors
Distributed Testing:
max distance between boxes, 20 feet; max distance total system, 200 feet
Test Rate:
256 points < 1 second
Mating Connectors:
64 point (2 row x 32 pins) 0.1" box header with latches
Computer Requirements:
CPU Speed:
1.6 GHz or faster,
OS:
Windows XP, Vista Business, Win 7
Hard Drive:
80 GB (or more)
RAM:
1 Gig (min) 2G (recommended)
Video Memory:
256 Meg RAM
USB Ports:
2 USB (min) 2 USB or more (recommended) (2.0 Compatible)
CD-ROM Drive and Sound card are required.
Serial Port:
1 port
Display resolution:
1024 X 768 or better.
Server Requirements:
Operating System:
Windows 2000 or 2003 Server.
RAM:
1 Gig.min, 2 Gig. (recommended)
Disk Space:
80 Gig.
Probe
For wire/pin identification during guided assembly, testing, and editing.
Power Required
105-130VAC, 60Hz 16 watts max
210-260VAC, 50Hz (optional)
Dimensions
5.4" x 6.6" x 2.6" (13.7 x 16.8 x 6.6 cm)
Weight
2.9 lbs. (1.3 kg)
Adapters

64 postion, Female, IDC Tyoe Ribbon Connector

64 Position, Female, .1" Dual Row Discrete Wire Connector

2' Ribbon Cable with 34 Pos. Female Connector mounted on one end only.

2' Ribbon Cable with 64 Pos. Female Connector mounted on both ends.

4' Ribbon Cable with 64 Pos. Female Connector mounted on both ends.
CR Current Software Version: 2012.2.0
(Where do you locate the machine version number on the CH2? Main screen, mid-right side of screen. List version and build numbers.
(Windows: 98 2nd, ME, 2K, XP)
WARNING: Before upgrading to a new software version, always BACK-UP your existing test files and your existing database file!
Current Software download Version: 2012.2.0
This test station software can be installed on Windows XP (Professional) and Win 7 (Professional). The 2012.2.0 version has added an enhanced Point Label user interface that is simular to the Touch1. With this release you will also be able to attach images to your connector graphics. Many more improvements to the CH2 custom instruction library.
PLEASE NOTE:
There is a fee associated with upgrading your software. Most software .EXE files are zipped with password protection! Call your Cirris sales representative with your PO or Credit Card information to receive the passcode for your selected software. Call toll free at 1-800-441-9910.
2012.2.0 Read me
Easy-Wire Station Software for Model CR - Vers 2012.2.0
WARNING: Before upgrading to a new software version, always BACK-UP your existing test files and your existing database file!
easy-wire Server Software for CH2, CR, CH+ testers-Vers 2012.4 (Nov 19, 2012
The easy-wire Server Software allows the operation of the CH2, CR, and CH+ test systems in a client server environment. This server software can be installed on Windows XP (Professional) and Winows 7 (Professional), Windows Server 2003, Windows Server 2008. The easy-wire Server Software allows centralized management of a single database file to be accessed and used by all easy-wire test stations. This provides centralized management of Security Settings, Test Programs, and Test Report data. You can manage your tester settings from any client connected to the easy-wire Server Software. Server and Clients must be the same version.
PLEASE NOTE: There is a fee associated with upgrading your software. Most software .EXE files are zipped with password protection! Call your Cirris sales representative with your PO or Credit Card information to receive the passcode for your selected software. Call toll free at 1-800-441-9910.
Download Vers. 2012.4.0.3050 Server Software
Cirris Server 2011.4.0 Release Notes